Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.427
Filtrar
1.
Int J Biol Macromol ; 263(Pt 1): 130341, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387637

RESUMO

Boron Nitride (h-BN) possesses unique qualities like increased thermal conductivity, non-toxic nature, and environmental friendliness; hence, it is a good reinforcing agent for chlorobutyl rubber (CIIR). Tannic acid (TA) holds excellent bio-functional properties and is considered as an exceptional bio-exfoliating agent. Hence, in this study, we have utilized the bio-exfoliating ability of TA to exfoliate h-BN and evaluate its efficiency in reinforcing the CIIR matrix. Results demonstrate the exceptional role of tannic acid in imparting multifunctionality to chlorobutyl rubber. CIIR matrix introduced with h-BN:TA (h-BN:TA/CIIR) display excellent mechanical performance due to the reinforcing effect shown by excess TA in addition to the exfoliating effect. In addition, h-BN:TA/CIIR composite exhibited superior antimicrobial activity against S. aureus. The retention of thermal decontamination efficiency of the composites with increase in the number of cycles ensures their promising application in the field of reusable gloves and chemical protective clothing. The exfoliated filler created a tortuous path inside the matrix which prevents the permeation of solvent. Hence the work intends to synergize the hydrophobic nature of h-BN, exfoliating capacity of TA and the barrier abilities of CIIR for the adsorption of oil from oil-water mixture and portrays the future of the trio in water purification.


Assuntos
Compostos de Boro , Nanocompostos , Polifenóis , Borracha , Staphylococcus aureus , Roupa de Proteção , Antibacterianos/farmacologia , Água
2.
Ann Work Expo Health ; 68(3): 280-294, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38266254

RESUMO

INTRODUCTION: Epoxy-based resin formulations are a frequent cause of allergic and irritant contact dermatitis in the construction and painting industries. Cases of epoxy resin contact dermatitis continue to persist across many sectors and are likely attributable to the growing use of epoxy products, including epoxy-based anti-corrosion coatings and inadequate skin protection. There are no published performance data against epoxy resins for garment materials and gloves to guide proper material selection in the workplace. OBJECTIVES: The objective of this study was to evaluate the resistance of 5 protective garment materials against permeation and penetration by bisphenol A diglycidyl ether and its higher oligomers found commonly in epoxy-based anti-corrosion coatings. METHODS: Five disposable garment materials were evaluated for resistance to bisphenol A diglycidyl ether monomers and oligomers during contact with epoxy-based anti-corrosion coatings, including latex gloves, nitrile gloves, Tyvek coveralls, polypropylene/polyethylene (PP/PE) coveralls, and a cotton T-shirt. A permeation test cell system was used to evaluate each garment material against an epoxy-based zinc-rich primer and an epoxy-based intermediate coating using a realistic application method. Glass fiber filters were used to collect permeating and penetrating epoxy resin during a 120-min test period. Bisphenol A diglycidyl ether quantification was performed with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry. Paint loading, coating thickness, and homogeneity were assessed on polytetrafluoroethylene filters sprayed in series in permeation test cells. RESULTS: Latex gloves provided the least resistance to permeation by BADGE in coating formulations, with a maximum cumulative permeation over the 2-h test interval of 21.7 ng cm-2 with the primer and 513.8 ng cm-2 with the intermediate coating product. Nitrile gloves were not permeated by either coating formulation. The Tyvek coveralls provided greater protection as compared to the PP/PE coveralls. The cotton T-shirt was penetrated by bisphenol A diglycidyl ether more frequently than any of the tested garment materials and resulted in a maximum cumulative penetration of 128 ng cm-2 with the primer and 28.0 ng cm-2 with the intermediate coating. CONCLUSION: Although all the garment materials evaluated during this study provided sufficient protection to prevent cumulative permeation in excess of the established acceptable permeation thresholds, the use of nitrile gloves and Tyvek coverall is highly recommended to minimize skin exposure to bisphenol A diglycidyl ether. We recommend cotton T-shirts to be used under Tyvek coveralls as a secondary layer of skin protection and for added comfort, but not as a primary protection layer.


Assuntos
Compostos Benzidrílicos , Dermatite de Contato , Compostos de Epóxi , Exposição Ocupacional , Humanos , Resinas Epóxi , Látex , Exposição Ocupacional/análise , Roupa de Proteção , Nitrilas
3.
Photodermatol Photoimmunol Photomed ; 40(1): e12933, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38288776

RESUMO

BACKGROUND: Skin cancer survivors are more vulnerable to subsequent skin cancers and other malignancies, but previous studies have not examined in detail their sun protection behavior prevalence by sociodemographic factors. We aimed to understand the sociodemographic disparities in the prevalence of three important types of sun protection behaviors: using sunscreen, seeking shade, and wearing protective clothing, among skin cancer survivors and those without skin cancer history. METHODS: We used the 2015 U.S. National Health Interview Survey to analyze 29,523 participants, of which 772 were skin cancer survivors and 28,751 were those without skin cancer history. We assessed overall and specific sun protection behavior prevalence based on using sunscreen, seeking shade, and wearing protective clothing. Weighted Poisson regression was used to estimate prevalence ratios. RESULTS: Melanoma and nonmelanoma skin cancer survivors had similar overall sun protection behavior (p > .05). Among all skin cancer survivors, 36.0% infrequently used sunscreen, 50.2% infrequently wore protective clothing, 47.8% infrequently sought shade, and 30.0% lacked frequent overall sun protection, which significantly differed from those without skin cancer history (p < .0001). The prevalence of frequent overall sun protection behavior was lower for those who were younger at survey, males, less educated, single or never married, or lived in poverty, regardless of their skin cancer history (p < .01). CONCLUSIONS: By identifying subpopulations with higher prevalence of infrequent sun protection among those with or without skin cancer history, our findings may encourage efforts to reduce sociodemographic disparities in sun protection behaviors and promote primary and tertiary skin cancer prevention.


Assuntos
Sobreviventes de Câncer , Neoplasias Cutâneas , Queimadura Solar , Masculino , Humanos , Estados Unidos/epidemiologia , Protetores Solares/uso terapêutico , Queimadura Solar/prevenção & controle , Comportamentos Relacionados com a Saúde , Neoplasias Cutâneas/epidemiologia , Neoplasias Cutâneas/prevenção & controle , Neoplasias Cutâneas/tratamento farmacológico , Roupa de Proteção
5.
Technol Health Care ; 32(1): 55-62, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37393442

RESUMO

BACKGROUND: The existing patient clothing is not suitable for patients that have to maintain a prone position for a long time after vitrectomy. OBJECTIVE: To investigate the effect of a new design of patient gowns for prone position patients after vitrectomy. METHOD: This study designed a kind of patient's gown for prone position patients. A non-randomized, concurrent, controlled study was conducted on 212 patients who met the inclusion criteria for the prone position after vitrectomy in Grade III at a Class A hospital department of ophthalmology in Zhejiang Province from April to August 2020. The experimental group (106 patients in prone position) and the control group (106 patients in common position) were managed by the same group of nurses. The study recorded and compared the comfort degree of patients' clothing used in the course of operation rehabilitation between the two groups and the satisfaction degree of doctors with nurses to patients' clothing used in the prone position. RESULTS: The satisfaction degree and comfort degree of patients and the health care providers in the experiment group were significantly higher than those in the control group (p< 0.001). CONCLUSION: The process of making patient gowns for prone position patients is simple, which can improve the safety and comfort of patients when they were in the prone position. The new design also facilitated the treatment and nursing procedures of the medical staff and improved satisfaction among patients and medical staff.


Assuntos
Roupa de Proteção , Vitrectomia , Humanos , Decúbito Ventral , Projetos de Pesquisa , Estudos de Coortes
6.
Risk Anal ; 44(2): 349-365, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37188329

RESUMO

This audience segmentation of visitors at coastal parks in Hawaii and North Carolina addresses an emergent natural resource management concern and risk to aquatic ecosystems: sunscreen chemical pollution. Four audiences were identified that correspond to different behavioral profiles: sunscreen protection tourists, multimodal sun protection tourists, in-state frequent park visitors, and frequent beachgoers who skip sunscreen. The second-largest audience, sunscreen protection tourists, represents 29% of visitors at Cape Lookout National Seashore and 25% at Kaloko-Honokohau National Historical Park. This group ranks of most concern for chemical pollution because they use sunscreen, but not typically mineral formulations or other methods such as protective clothing, and they have lower levels of sunscreen chemical issue awareness. The identification of similar audience segments across regions with differing cultural characteristics and sunscreen regulation status suggests the robustness of the model and its indicator variables, with implications for both environmental protection and public health. Further, coastal visitors' interest in enacting pro-environmental sun protection behaviors during their next park or beach visit indicates the potential for natural resource managers to holistically address risks in both domains through targeted interventions with audiences of most concern.


Assuntos
Queimadura Solar , Protetores Solares , Humanos , Protetores Solares/uso terapêutico , Queimadura Solar/tratamento farmacológico , Queimadura Solar/etiologia , Queimadura Solar/prevenção & controle , Ecossistema , Roupa de Proteção/efeitos adversos , Recursos Naturais
8.
Int J Occup Saf Ergon ; 30(1): 205-214, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37422729

RESUMO

A liquid-cooled garment with active cooling function can make up for deficiency of the human thermoregulatory system and passive thermal insulation of the firefighting protective suit. Fabrics treated at different inlet temperatures and pipeline intervals were applied in multilayered liquid-cooled fabric assemblies (LCFAs). The heat absorbed by the skin and the second-degree burn time were evaluated by the stored energy test under low heat radiation. Results indicated that the thermal protective performance of the LCFAs was significantly improved, with the second-degree burn time increasing more than 50% on average. There was a strong negative correlation between the thermal protective performance and cooling effect under different pipeline intervals, while the negative correlation was weak for different inlet temperatures. The results gained from this study may provide valuable insight for design of the inlet temperature and pipeline interval of a liquid-cooled system in the firefighting protective suit.


Assuntos
Regulação da Temperatura Corporal , Roupa de Proteção , Humanos , Temperatura , Temperatura Baixa , Temperatura Alta
9.
Small ; 20(1): e2304705, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37653612

RESUMO

Extreme environments can cause severe harm to human health, and even threaten life safety. Lightweight, breathable clothing with multi-protective functions would be of great application value. However, integrating multi-protective functions into nanofibers in a facile way remains a great challenge. Here, a one-step co-electrospinning-electrospray strategy is developed to fabricate a superhydrophobic multi-protective membrane (S-MPM). The water contact angle of S-MPM can reach up to 164.3°. More importantly, S-MPM can resist the skin temperature drop (11.2 °C) or increase (17.2 °C) caused by 0 °C cold or 70 °C hot compared with pure electrospun membrane. In the cold climate (-5 °C), the anti-icing time of the S-MPM is extended by 2.52 times, while the deicing time is only 1.45 s due to the great photothermal effect. In a fire disaster situation, the total heat release and peak heat release rate values of flame retarded S-MPM drop sharply by 24.2% and 69.3%, respectively. The S-MPM will serve as the last line of defense for the human body and has the potential to trigger a revolution in the practical application of next-generation functional clothing.


Assuntos
Roupa de Proteção , Temperatura Cutânea , Humanos , Temperatura Baixa , Temperatura Alta , Ambientes Extremos
10.
Int J Occup Saf Ergon ; 30(1): 90-99, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37596795

RESUMO

Fit of fire boots is a crucial factor in the safety and performance of firefighters on the hostile fireground. Firefighters have reported that ill-fitting fire boots restrict their lower body movement and sometimes cause very dangerous situations by falling off behind the wearer. By using computed tomography, this study demonstrates the potential to quantify and visualize the fit of fire boots, which previously relied on subjective feedback from the wearers. The high-resolution three-dimensional (3D) models of two fire boot products allowed a detailed observation and measurement of the internal space of the boots. Also, the boot's internal dimension was compared to the foot measurement of local firefighters, showing the significant differences between the two boots. Lastly, simulation wrapping the 3D scanned foot with the boot revealed large void spaces around the toe box and ankle, as well as the narrower ball width of the boot than the foot.


Assuntos
Roupa de Proteção , Sapatos , Humanos , Pé/diagnóstico por imagem , Pé/anatomia & histologia , Extremidade Inferior , Tomografia
11.
Mil Med ; 189(1-2): e448-e453, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-37647618

RESUMO

Behind armor blunt trauma (BABT) is a non-penetrating injury caused by energy transfer and rapid deformation of protective body armor. Although modern military body armor is designed to prevent penetrating trunk injuries, high-energy projectiles can produce a significant energy transfer to tissues behind the armor and inflict injuries such as fractures or organ contusions. However, knowledge of BABT is limited to biomechanical and cadaver modeling studies and rare case reports. We report two cases of BABT resulting from close-range fire and discuss the potential implications for triaging patients with BABT in battlefield scenarios. In the first case, a 19-year-old male soldier sustained a single close-range 5.56-mm assault rifle gunshot to his chest body armor. The soldier initially reported mild pain in the parasternal region and assessment revealed a 4 cm × 3 cm skin abrasion. Following emergency department evaluation, the soldier was diagnosed with a non-displaced transverse fracture of the sternal body. In the second case, a 20-year-old male sustained five machine gun bullets (7.62 mm) to his body armor. Computed tomography of the chest revealed pulmonary contusions in the right lower and middle lobes. Both soldiers achieved full recovery and returned to combat duty within several weeks. These cases highlight the potential risks of energy transfer from high-velocity projectiles impacting body armor and the need for frontline providers to be aware of the risk of underlying blunt injuries. Further reporting of clinical cases and modeling studies using high-velocity projectiles could inform recommendations for triaging, evacuating, and assessing individuals with BABT.


Assuntos
Contusões , Traumatismos Torácicos , Ferimentos por Arma de Fogo , Ferimentos não Penetrantes , Masculino , Humanos , Adulto Jovem , Adulto , Roupa de Proteção , Ferimentos por Arma de Fogo/complicações , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico , Contusões/complicações
13.
Radiat Prot Dosimetry ; 200(4): 333-338, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38124656

RESUMO

The lead apron plays a crucial role in radiation protection and is extensively used in medical institutions. Periodic performance evaluations, involving visual inspections and transmission imaging, are conducted annually. This research aims to propose a performance evaluation method for 0.5 mm lead aprons used in nuclear medicine departments. The experiments were conducted using transmission imaging and source-based evaluation methods, involving two lead aprons with <1 year of use and two other aprons used for over 10 years. The experimental results indicate that using 50 kVp for transmission imaging is appropriate to detect cracks in the lead aprons. Additionally, in the case of lead aprons used for >10 years, the measured attenuation rate was found to be ~3-5% lower, depending on the measurement method. Consequently, a performance evaluation, including crack detection and actual attenuation rate measurements, should be carried out for lead aprons used long-term to ensure efficacy of radiation protection.


Assuntos
Medicina Nuclear , Proteção Radiológica , Doses de Radiação , Proteção Radiológica/métodos , Cintilografia , Roupa de Proteção
14.
Medicine (Baltimore) ; 102(48): e36447, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38050291

RESUMO

BACKGROUND: The present study aimed to evaluate the degree of radiation shielding effects according to lead equivalent thickness and distance during C-arm fluoroscopy-guided lumbar interventions. METHODS: The exposure time and air kerma were recorded using a fluoroscope. The effective dose (ED) was measured with and without the shielding material of the lead apron using 2 dosimeters at 2 positions. According to the lead equivalent thickness of the shielding material and distance from the side of the table, the groups were divided into 4 groups: group 1 (lead equivalent thickness 0.6 mm, distance 0 cm), group 2 (lead equivalent thickness 0.6 mm, distance 5 cm), group 3 (lead equivalent thickness 0.3 mm, distance 0 cm), and group 4 (lead equivalent thickness 0.3 mm, distance 5 cm). Mean differences such as air kerma, exposure time, ED, and ratio of EDs (ED with protector/ED without protector) were analyzed. RESULTS: A total of 400 cases (100 cases in each group) were collected. The ratio of ED was significantly lower in groups 1 and 2 (9.18 ±â€…2.78% and 9.56 ±â€…3.29%, respectively) when compared to that of groups 3 and 4 (21.93 ±â€…4.19% and 21.53 ±â€…4.30%, respectively). The reductive effect of a 5-cm distance was 33.3% to 36.1% when comparing the ED between groups 1 and 2 and groups 3 and 4. CONCLUSIONS: The 0.3- and 0.6-mm lead equivalent thickness protectors have a radiation attenuation effect of 78.1% to 78.5% and 90.4% to 90.8%, respectively. The 5-cm distance from the side of the table reduces radiation exposure by 33.3% to 36.1%.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Fluoroscopia/efeitos adversos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Roupa de Proteção , Equipamentos de Proteção , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle
16.
J Med Syst ; 48(1): 7, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38157145

RESUMO

Virtual assistants (VAs) are conversational agents that are able to provide cognitive aid. We developed a VA device for donning and doffing personal protective equipment (PPE) procedures and compared it to live human coaching to explore the feasibility of using VAs in the anesthesiology setting. An automated, scalable, voice-enabled VA was built using the Amazon Alexa device and Alexa Skills application. The device utilized voice-recognition technology to allow a touch-free interactive user experience. Audio and video step-by-step instructions for proper donning and doffing of PPE were programmed and displayed on an Echo Show device. The effectiveness of VA in aiding adherence to PPE protocols was compared to traditional human coaching in a randomized, controlled, single-blinded crossover design. 70 anesthesiologists, anesthesia assistants, respiratory therapists, and operating room nurses performed both donning and doffing procedures, once under step-by-step VA instructional guidance and once with human coaching. Performance was assessed using objective performance evaluation donning and doffing checklists. More participants in the VA group correctly performed the step of "Wash hands for 20 seconds" during both donning and doffing tests. Fewer participants in the VA group correctly performed the steps of "Put cap on and ensure covers hair and ears" and "Tie gown on back and around neck". The mean doffing total score was higher in the VA group; however, the donning score was similar in both groups. Our study demonstrates that it is feasible to use commercially available technology to create a voice-enabled VA that provides effective step-by-step instructions to healthcare professionals.


Assuntos
Anestesiologia , Humanos , Pessoal de Saúde , Equipamento de Proteção Individual , Roupa de Proteção , Estudos Cross-Over , Método Simples-Cego
17.
Braz J Microbiol ; 54(4): 3321-3325, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919460

RESUMO

In this prospective study, we aimed to investigate whether surgical gowns become contaminated during surgery. Samples from the gowns of five surgeons during 19 surgeries were collected using sterile swabs in circular standard delimited areas on both wrists and the mid-chest at three time-points: immediately before surgical incision (t=0), 30 min (t=30), and 60 min (t=60) later. Additionally, at t=0 and t=60, three settle plates of plate count agar were positioned at 1.5 m from the ground and remained open for 20 min. The operating room temperature and relative humidity were monitored. The swabs were cultivated and incubated, and colony-forming units per gram (CFU/g) counts were measured. The CFU/g counts for bacteria or fungi did not differ among the three sampling sites. The surgeons' lateral dominance in manual dexterity did not influence the gowns' contamination. There were significant variations in the temperature and relative humidity over time, but not in the CFU/g counts. In conclusion, during the first hour of surgery, surgical gowns did not become a source of contamination and are an effective barrier against bacterial and fungal contamination even under non-standard surgical environmental conditions.


Assuntos
Vestimenta Cirúrgica , Estudos Prospectivos , Roupa de Proteção/microbiologia , Salas Cirúrgicas , Bactérias
18.
Mil Med ; 188(Suppl 6): 598-605, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37948200

RESUMO

INTRODUCTION: For behind armor blunt trauma (BABT), recent prominent BABT standards for chest plate define a maximum deformation distance of 44 mm in clay. It was developed for soft body armor applications with limited animal, gelatin, and clay tests. The legacy criterion does not account for differing regional thoracoabdominal tolerances to behind armor-induced injury. This study examines the rationale and approaches used in the legacy BABT clay criterion and presents a novel paradigm to develop thoracoabdominal regional injury risk curves. MATERIALS AND METHODS: A review of the original military and law enforcement studies using animals, surrogates, and body armor materials was conducted, and a reanalysis of data was performed. A multiparameter model analysis describes survival-lethality responses using impactor/projectile (mass, diameter, and impact velocity) and specimen (weight and tissue thickness) variables. Binary regression risk curves with ±95% confidence intervals (CIs) and peak deformations from simulant tests are presented. RESULTS: Injury risk curves from 74 goat thorax tests showed that peak deflections of 44.7 mm (±95% CI: 17.6 to 55.4 mm) and 49.9 mm (±95% CI: 24.7 to 60.4 mm) were associated with the 10% and 15% probability of lethal outcomes. 20% gelatin and Roma Plastilina #1 clay were stiffer than goat. The clay was stiffer than 20% gelatin. Penetration diameters showed greater variations (on a test-by-test basis, difference 36-53%) than penetration depths (0-12%) across a range of projectiles and velocities. CONCLUSIONS: While the original authors stressed limitations and the importance of additional tests for refining the 44 mm recommendation, they were not pursued. As live swine tests are effective in developing injury criteria and the responses of different areas of the thoracoabdominal regions are different because of anatomy, structure, and function, a new set of swine and human cadaver tests are necessary to develop scaling relationships. Live swine tests are needed to develop incapacitation/lethal injury risk functions; using scaling relationships, human injury criteria can be developed.


Assuntos
Balística Forense , Ferimentos não Penetrantes , Humanos , Suínos , Animais , Gelatina , Argila , Roupa de Proteção , Ferimentos não Penetrantes/complicações , Ferimentos não Penetrantes/diagnóstico , Cabras
19.
Am J Infect Control ; 51(12): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37690482

RESUMO

BACKGROUND: Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance. METHODS: Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels. RESULTS: Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas. CONCLUSIONS: The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.


Assuntos
Isolamento de Pacientes , Roupa de Proteção , Humanos , Equipamento de Proteção Individual , Equipamentos Descartáveis
20.
Physiol Meas ; 44(10)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37703905

RESUMO

Objective. Exercise-heat strain estimation approaches often involve combinations of body core temperature (Tcore), skin temperature (Tsk) and heart rate (HR). A successful existing measure is the 'Physiological Strain Index' (PSI), which combines HR and Tcore values to estimate strain. However, depending on variables such as aerobic fitness and clothing, the equation's 'maximal/critical' Tcore must be changed to accurately represent the strain, in part because high Tsk (small Tcore-Tsk) can increase cardiovascular strain and thereby negatively affect performance. Here, an 'adaptive PSI' (aPSI) is presented where the original PSI Tcorecriticalvalue is 'adapted' dynamically by the delta between Tcore and Tsk.Approach. PSI and aPSI were computed for athletes (ELITE,N= 11 male and 8 female, 8 km time-trial) and soldiers in fully encapsulating personal protective equipment (PPE,N= 8 male, 2 km approach-march). While these were dissimilar events, it was anticipated given that the clothing and work rates would elicit similar very-high exercise-heat strain values.Main results. Mean end HR values were similar (∼180 beats min-1) with higher Tcore = 40.1 ± 0.4 °C for ELITE versus PPE 38.4 ± 0.6 °C (P< 0.05). PSI end values were different between groups (P< 0.01) and appeared 'too-high' for ELITE (11.4 ± 0.8) and 'too-low' for PPE (7.6 ± 2.0). However, aPSI values were not different (9.9 ± 1.4 versus 9.0 ± 2.5 versus;p> 0.05) indicating a 'very high' level of exercise-heat strain for both conditions.Significance. A simple adaptation of the PSI equation, which accounts for differences in Tcore-to-Tsk gradients, provides a physiological approach to dynamically adapt PSI to provide a more accurate index of exercise-heat strain under very different working conditions.


Assuntos
Temperatura Corporal , Transtornos de Estresse por Calor , Humanos , Masculino , Feminino , Temperatura Corporal/fisiologia , Temperatura Alta , Exercício Físico/fisiologia , Atletas , Transtornos de Estresse por Calor/diagnóstico , Frequência Cardíaca/fisiologia , Regulação da Temperatura Corporal/fisiologia , Roupa de Proteção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...